RAUPYAM LABS · VERIFICATION REGISTER
Raw Material Files
What we ordered, what arrived, what the certificate claimed, and what we were actually able to verify — including the times the two did not match.
In pharmacy you do not accept a raw material because the paperwork says so. Every lot gets an identity test. Cosmetics mostly does not work that way: the certificate of analysis arrives with the drum, nobody checks it, and the number on the label is inherited rather than measured.
This is our record of doing it the other way. Every material we buy is listed here, whatever the outcome, with the evidence behind each verdict stated plainly — including when the evidence is the supplier’s rather than ours, and including the materials we still cannot identify. Each row links to the full file.
5 supplies across 4 files · 1 matched their documentation · 1 unidentified · 3 open
Polyglyceryl-6 Polyricinoleate
CAS 114355-43-0
MALDI-TOF spacings match glyceryl (74.037) and ricinoleoyl (280.240) units; six wet-chemistry values internally consistent. Supplier's data, not repeated by us.
- Certificate
- Yes, with MALDI-TOF and GPC
- Evidence
- Supplier's
- Files
- 04
Biosaccharide Gum-1
No CAS claimed
Behaviour in solution against a hydroxyethylcellulose control at the same concentration. Identity not established.
- Certificate
- None — not provided on request
- Evidence
- Ours
- Files
- 03
Biosaccharide Gum-4
No CAS claimed
Behaviour in solution against a hydroxyethylcellulose control. Visually indistinguishable from Gum-1 as received.
- Certificate
- None — not provided on request
- Evidence
- Ours
- Files
- 03
Isobutylamido Thiazolyl Resorcinol
CAS 1428450-95-6
Nothing. No reference standard is obtainable for a patented active, which is the subject of the file.
- Certificate
- Yes
- Evidence
- None yet
- Files
- 02
Polyglyceryl-6 Polyricinoleate
CAS 107615-51-0
Pour behaviour and performance in an otherwise identical emulsion. Identity not established.
- Certificate
- None provided
- Evidence
- Ours
- Files
- 01, 04
Unidentified means we could not establish what the material is, not that anything was misrepresented. Evidence records whether the data behind a verdict was generated on our instruments or supplied with the material. Suppliers are named inside the files where there is something to credit, and not otherwise.
Corrections and contributions
If you have bought any of these materials and measured them, we would like to hear what you found. If anything in this register is wrong, tell us and we will correct it in place, dated, with the correction logged rather than quietly edited away.
Write to us